Fibre cable is the best method to future proof against unforseen threats. 10.3.5.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2295] Agencies SHOULD use fibre optic cabling. 10.3.6. Cabling inspection 10.3.6.R.01. Rationale In a shared facility it is important that cabling systems are inspected for illicit tampering and damage on a regular basis and have stricter controls than a non-shared facility. 10.3.6.C.01. ControlSystem Classification(s): Top Secret; Compliance: MUST [CID:2299] In TOP SECRET areas, cables MUST be fully inspectable for their entire length. 10.3.6.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2298] Cabling SHOULD be inspectable at a minimum of five-metre intervals. 10.3.7. Cables sharing a common reticulation system 10.3.7.R.01. Rationale In a shared facility with another government agency, tighter controls may be required for sharing reticulation systems. Note also the red/black separation requirements in paragraph 10.1.5. 10.3.7.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2302] Approved cable groups SHOULD have either a dividing partition or a visible gap between the individual cable groups. If the partition or gap exists, cable groups may share a common reticulation system. 10.3.8. Enclosed cable reticulation systems 10.3.8.R.01. Rationale In a shared facility with another government agency, TOP SECRET cabling is enclosed in a sealed reticulation system to restrict access and control cable management. 10.3.8.C.01. ControlSystem Classification(s): Top Secret; Compliance: SHOULD [CID:2305] The front covers of conduits, ducts and cable trays in floors, ceilings and of associated fittings that contain TOP SECRET cabling, SHOULD be clear plastic. 10.3.9. Cabling in walls 10.3.9.R.01. Rationale In a shared facility with another government agency, cabling run correctly in walls allows for neater installations while maintaining separation and inspectability requirements. Controls are slightly more stringent than in a non-shared facility. 10.3.9.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2308] Cabling from cable trays to wall outlets SHOULD run in flexible or plastic conduit. 10.3.10. Wall penetrations 10.3.10.R.01. Rationale Wall penetrations by cabling, requires the integrity of the classified area to be maintained. All cabling is encased in conduit with no gaps in the wall around the conduit. This prevents any visual access to the secure area. 10.3.10.C.01. ControlSystem Classification(s): Top Secret; Compliance: SHOULD [CID:2311] For wall penetrations that exit into a lower classified area, cabling SHOULD be encased in conduit with all gaps between the conduit and the wall filled with an appropriate sealing compound. 10.3.11. Power reticulation 10.3.11.R.01. Rationale In a shared facility with lesser-classified systems, it is important that TOP SECRET systems have control over the power system to prevent denial of service by deliberate or accidental means. 10.3.11.C.01. ControlSystem Classification(s): Top Secret; Compliance: SHOULD [CID:2314] TOP SECRET facilities SHOULD have a power distribution board, separately reticulated, located within the TOP SECRET area and supply UPS power to all equipment. 10.3.12. Power Filters 10.3.12.R.01. Rationale Power filters are used to provide a filtered (clean) power supply and reduce opportunity for technical attacks. See also10.1.32. 10.3.12.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2317] Power filters SHOULD be used to provide a filtered power supply and reduce opportunity for technical attacks. 10.3.13. Cabinet separation 10.3.13.R.01. Rationale 102 Version_3.5__January-2022

Select target paragraph3

Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents