Having a visible gap between cabinets facilitates inspection for any unauthorised, malicious or cross patch cabling.
10.3.13.C.01. ControlSystem Classification(s): Top Secret; Compliance: SHOULD
[CID:2320]
TOP SECRET cabinets SHOULD have a visible gap to separate them from lower classified cabinets.
10.4. Cable Management for Shared Non-Government Facilities
Objective
10.4.1. Cable management systems are implemented in shared non-government facilities to minimise risks to data and information.
Context
Scope
10.4.2. This section provides specific requirements for cabling installed in facilities shared by agencies and non-government organisations. This section is to be
applied in addition to common requirements for cabling as outlined in Section 10.1 - Cable Management Fundamentals section.
Applicability of controls within this section
10.4.3. The controls within this section are applicable only to communications infrastructure located within facilities in New Zealand. For deployable platforms
or facilities outside New Zealand, Emanation Security Threat Assessments (Section 10.7) of this chapter of this manual MUST be consulted.
Rationale & Controls
10.4.4.
Use of fibre optic cabling
10.4.4.R.01.
Rationale
Fibre optic cabling is essential in a shared non-government facility. Fibre optic cabling does not produce and is not influenced by
electromagnetic emanations; as such it offers the highest degree of protection from electromagnetic emanation effects especially in a shared
non-government facility where an agency’s controls may have a limited effect outside the agency controlled area.
10.4.4.R.02.
Rationale
Fibre optic cable is more difficult to tap than copper cabling and anti-tampering monitoring can be employed to detect tampering.
10.4.4.R.03.
Rationale
Many more fibres can be run per cable diameter than wired cables, reducing cable infrastructure costs.
10.4.4.C.01.
ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:2335]
In TOP SECRET areas, agencies MUST use fibre optic cabling.
10.4.4.C.02.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2336]
Agencies SHOULD use fibre optic cabling.
10.4.5.
Cabling inspection
10.4.5.R.01.
Rationale
In a shared non-government facility, it is imperative that cabling systems be inspectable for tampering and damage on a regular basis
particularly where higher threat levels exist or where threats are unknown.
10.4.5.C.01.
ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:2340]
In TOP SECRET areas, cables MUST be fully inspectable for their entire length.
10.4.5.C.02.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2341]
Cabling SHOULD be inspectable at a minimum of five-metre intervals.
10.4.6.
Cables sharing a common reticulation system
10.4.6.R.01.
Rationale
In a shared non-government facility, tighter controls are placed on sharing reticulation systems as the threats attributable to tampering and
damage are increased.
10.4.6.C.01.
ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:2344]
In TOP SECRET areas, approved cable groups can share a common reticulation system but MUST have either a dividing partition or a visible
gap between the differing cable groups.
10.4.6.C.02.
ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:2345]
TOP SECRET cabling MUST run in a non-shared, enclosed reticulation system.
10.4.6.C.03.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2346]
Approved cable groups can share a common reticulation system but SHOULD have either a dividing partition or a visible gap between the
differing cable groups.
10.4.7.
Enclosed cable reticulation systems
10.4.7.R.01.
Rationale
In a shared non-government facility, TOP SECRET cabling is enclosed in a sealed reticulation system to prevent access and control cable
management.
10.4.7.C.01.
103
ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:2349]
Version_3.5__January-2022