10.6.25.R.01. Rationale
Standardised layout of rack and cabinets facilitates maintenance and reduces risk of accidental cross-connects. Cabinets may also include UPS
or other power supply equipment which is most appropriately housed at the bottom of the cabinet. RED/BLACK separations of equipment and
cables should be maintained. Refer to 10.6.16 in the Context above.
10.6.25.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: SHOULD
[CID:5610]
Agencies SHOULD arrange the installation of cabinets as follows:
RED equipment at the top;
BLACK equipment in the centre;
Power equipment at the bottom.
10.6.26. Rack Diagrams
10.6.26.R.01. Rationale
A rack diagram is a two-dimensional elevation drawing showing the layout or arrangement of equipment on a rack. It may show the front and
the rear elevation of the rack layout. It does not have to be drawn to scale. This provides essential information when maintenance or
development is undertaken or new equipment installed.
10.6.26.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:5613]
Agencies SHOULD record equipment layouts and other relevant information on rack diagrams.
10.6.27. Fly lead installation
10.6.27.R.01. Rationale
Keeping the lengths of fly leads to a minimum prevents clutter around desks, prevents damage to fibre optic cabling and reduces the chance of
cross patching and tampering. If lengths become excessive then agencies will need to treat the cabling as infrastructure and run it in conduit or
fixed infrastructure such as desk partitioning. Secure patch cords properly to keep them off the floor or the base of racks, where they can be
stepped on.
10.6.27.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: SHOULD
[CID:2438]
Agencies SHOULD ensure that the fibre optic fly leads used to connect wall outlets to IT equipment either:
do not exceed 5m in length; or
if they exceed 5m in length:
are run in the facility’s fixed infrastructure in a protective and easily inspected pathway;
are clearly labelled at the equipment end with the wall outlet designator; and
are approved by the Accreditation Authority.
10.6.28. Earthing and Bonding
10.6.28.R.01. Rationale
It is important that any metal trays or metal catenary are earthed for both safety and to avoid creating any fortuitous conductors. Effective
earthing also depends on properly bonding all conductive elements of a cabinet, rack or case housing any equipment. Bonding requires good
mechanical and electrical connection between conductive elements through bolts and nuts and/or earth straps or jump leads. Specialist
bonding hardware is widely available.
10.6.28.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST
[CID:5621]
All earthing points MUST be equipotentially bonded.
10.6.28.C.02. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST
[CID:5623]
All conductive elements of a cabinet, rack or case housing any equipment MUST be earth bonded.
10.6.29. Cable Management
10.6.29.R.01. Rationale
Good cable management facilitates maintenance, promotes air flow and cooling, reduces risk of accidental cross-connects or disconnects and
supports safe operation.
10.6.29.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST
[CID:5626]
Cabinet rails MUST be installed to:
provide adequate room for patch cables and wire managers;
provide adequate space for cable management at front, sides, and rear; and
arrange switches and patch panels to minimize patching between cabinets & racks.
10.6.30. Labelling Cables
10.6.30.R.01. Rationale
The labelling principles include the following:
Labelling is logical and consistent, across all locations, matching the project drawings;
The labelling scheme identifies any associated physical locations (building, room, cabinet, rack, port, etc.);
Labelling is easily read, durable, and capable of surviving for the life of the component that was labelled;
111
Version_3.5__January-2022
Select target paragraph3
Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents