person visiting;
contact details for person visiting; and
date and time in and out.
9.4.10.
Separate visitor logs
9.4.10.R.01.
Rationale
Maintaining a separate visitor log for TOP SECRET areas assists in enforcing the need-to-know principle. General visitors do not need-to-know of
personnel that have visited TOP SECRET areas.
9.4.10.C.01.
ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:1589]
Agencies with a TOP SECRET area within a larger facility MUST maintain a separate log from any general visitor log.
10. Infrastructure
10.1. Cable Management Fundamentals
Objective
10.1.1. Cable management systems are designed to support the integration of systems across government facilities, assist maintenance and engineering
changes, as well as minimise the opportunity for tampering or unauthorised changes to cable systems.
Context
Scope
10.1.2. This section covers information relating to cable distribution systems used in facilities within New Zealand. When designing cable management
systems, Section 10.5 - Cable Labelling and Registration and Section 10.6 - Cable Patching of this chapter also apply.
Applicability of controls within this section
10.1.3. The controls within this section are applicable only to communications infrastructure located within facilities in New Zealand. For deployable platforms
or facilities outside of New Zealand Emanation Security Threat Assessments (Section 10.7) of this chapter of this manual MUST be consulted.
Common implementation scenarios
10.1.4. This section provides common requirements for non-shared facilities. Specific requirements for facilities shared between agencies and facilities shared
with non-government entities can be found in subsequent sections of this chapter.
Red/Black Concept and Cable Separation
10.1.5. The RED/BLACK concept is the separation of electrical and electronic circuits, devices, equipment cables, connectors, components and systems that
transmit store or process national security information from non-national security information. The RED/BLACK concept is sometimes described as
RED/BLACK architecture or RED/BLACK engineering.
10.1.6. The RED/BLACK concept should not be confused with the generic description HIGH/LOW or HIGH SIDE/LOW SIDE. In this context, HIGH refers
to systems classified CONFIDENTIAL and above and LOW refers to systems classified RESTRICTED and below. While these concepts are similar and
often used interchangeably, it is important to recognise that information does not usually change classification. The signal or transmission, however,
may transit both RED and BLACK systems in order to reach its intended destination. It is important to note that systems carrying a particular
classification may also carry information at ALL lower classifications BUT NOT any higher classifications.
10.1.7. An example is the use of radio transmissions or Wi-Fi where the information may hold a HIGH classification and originate inRED equipment but once
transmission occurs the signal is BLACK as radio and Wi-Fi signals can be detected by anyone within range.
10.1.8. This also leads to the situation where some equipment may have bothRED and BLACK elements. Examples include Wi-Fi Access Points and
encryption devices. RED Information in a BLACK environment is invariably protected by encryption and a variety of technical countermeasures.
10.1.9. All cables with metal conductors (the signal carrier, the grounding element, the strengthening member or an armoured outer covering) can act as
fortuitous signal conductors allowing signals to escape or to cross-contaminate other cables and signals. This provides a path for the exploitation of
signals, data and information.
10.1.10. A fundamental control is the separation of cables and related equipment with sufficient distance between them to prevent cross-contamination.
Cable trays
10.1.11. Where copper or a combination of copper and fibre cables are used, cable trays will provide separation, assist cable management and enhance cable
protection. While preferable to separate RED cables of different systems for cable management purposes, the most important element is to maintain
RED/BLACK separation.
10.1.12. It is preferable that cable trays contain dividers. Some cable trays provide only a single receptacle for cables (no dividers). If dividers are not available,
multi-core fibre cables should be used. Cables of similar classifications should be bundled. A typical cable tray layout with dividers is depicted below:
92