PSR Mandatory
Requirements
GOV3, GOV8, INFOSEC1, INFOSEC2,
INFOSEC3 and INFOSEC4
http://www.protectivesecurity.govt.nz
https://www.protectivesecurity.govt.nz/governance/mandatory-requirements-2/
https://www.protectivesecurity.govt.nz/information-security/mandatory-requirements2/
PSR content
protocols
Management protocol for information
security
https://www.protectivesecurity.govt.nz/information-security/management-protocol/
PSR requirements
Self assessment & reporting
https://www.protectivesecurity.govt.nz/self-assessment-and-reporting/
Transacting online with the public
https://www.protectivesecurity.govt.nz/information-security/managing-specific-
sections
Managing specific
scenarios
scenarios/transacting-online-with-the-public/
Rationale & Controls
4.3.16.
Independence of auditors
4.3.16.R.01.
Rationale
As there can be a perceived conflict of interest in the system owner assessing the security of their own system it is important that the auditor is
demonstrably independent. This does not preclude an appropriately qualified system owner from assessing the security of a system that they
are not responsible for.
4.3.16.C.01.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:562]
Agencies SHOULD ensure that auditors conducting audits are able to demonstrate independence and are not also the system owner or
certification authority.
4.3.17.
Audit preparation
4.3.17.R.01.
Rationale
Ensuring that the system owner has approved the system architecture and associated information security documentation will assist auditors in
determining the scope of work for the first stage of the audit.
4.3.17.C.01.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:565]
Prior to undertaking the audit the system owner MUST approve the system architecture and associated information security documentation.
4.3.18.
Audit (first stage)
4.3.18.R.01.
Rationale
Auditing against the risk assessment and subsequent controls selection is preferable to a ‘checklist’ approach where all controls in the NZISM
are checked for selection and implementation irrespective of applicability.
4.3.18.R.02.
Rationale
The purpose of the first stage of the audit is to determine that the system and security architecture (including information security
documentation) is based on sound information security principles and has addressed all applicable controls from this manual. During this
stage the statement of applicability for the system will also be assessed along with any justification for non-compliance with applicable controls
from this manual.
4.3.18.R.03.
Rationale
Without implementing the controls for a system their effectiveness cannot be assessed during the second stage of the audit.
4.3.18.C.01.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:569]
The SecPol, SRMP, SSP, SOPs and IRP documentation MUST be reviewed by the auditor to ensure that it is comprehensive and appropriate for
the environment the system is to operate within.
4.3.18.C.02.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:570]
The Information Security Policy (SecPol) MUST be reviewed by the auditor to ensure that all applicable controls specified in this manual are
addressed.
4.3.18.C.03.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:571]
The system and security architecture (including information security documentation) SHOULD be reviewed by the auditor to ensure that it is
based on sound information security principles and meets information security requirements, including the NZISM.
4.3.18.C.04.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:572]
The Information Security Policy (SecPol) SHOULD be reviewed by the auditor to ensure that policies have been developed or identified by the
agency to protect classified information that is processed, stored or communicated by its systems.
4.3.18.C.05.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:573]
The system owner SHOULD provide a statement of applicability for the system which includes the following topics:
the baseline of this manual used for determining controls;
controls that are, and are not, applicable to the system;
controls that are applicable but are not being complied with; and
any additional controls implemented as a result of the SRMP.