Agencies MUST ensure that keys or equivalent access mechanisms to server rooms, communications rooms and security containers are
appropriately controlled.
8.2.6.C.02.
ControlSystem Classification(s): All Classifications; Compliance: MUST NOT
[CID:1354]
Agencies MUST NOT leave server rooms, communications rooms or security containers in an unsecured state unless the server room is
occupied by authorised personnel.
8.2.7.
Administrative measures
8.2.7.R.01.
Rationale
Site security plans (SitePlan), the physical security equivalent of the SSP and SOPs for systems, are used to document all aspects of physical
security for systems. Formally documenting this information ensures that standards, controls and procedures can easily be reviewed by
security personnel.
8.2.7.C.01.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:1357]
Agencies MUST develop a Site Security Plan (SitePlan) for each server and communications room. Information to be covered includes, but is not
limited to:
a summary of the security risk review for the facility the server or communications room is located in;
roles and responsibilities of facility and security personnel;
the administration, operation and maintenance of the electronic access control system or security alarm system;
key management, the enrolment and removal of system users and issuing of personal identification number codes and passwords;
personnel security clearances, security awareness training and regular briefings;
regular inspection of the generated audit trails and logs;
end of day checks and lockup;
reporting of information security incidents; and
what activities to undertake in response to security alarms.
8.2.8.
No-lone-zones
8.2.8.R.01.
Rationale
Areas containing particularly sensitive materials or IT equipment can be provided with additional security through the use of a designated nolone-zone. The aim of this designation is to enforce two-person integrity, where all actions are witnessed by at least one other person.
8.2.8.C.01.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:1360]
Agencies operating no-lone-zones MUST suitably signpost the area and have all entry and exit points appropriately secured.
8.3. Network Infrastructure
Objective
8.3.1.
Network infrastructure is protected by secure facilities and the use of encryption technologies.
Context
Scope
8.3.2.
This section covers information relating to the physical security of network infrastructure. Information relating to servers, network devices and IT
equipment can be found in other sections of this chapter. Additionally, information on using encryption for infrastructure in unsecure areas can be
found in Section 17.1 - Cryptographic Fundamentals.
Rationale & Controls
8.3.3.
Network infrastructure in secure areas
8.3.3.R.01.
Rationale
Network infrastructure is considered to process information being communicated across it and as such needs to meet the minimum physical
security requirements for processing classified information as specified in the PSR Management protocol for physical security, with supporting
document – Storage requirements for electronic information in ICT facilities.
8.3.3.R.02.
Rationale
The physical security requirements for network infrastructure can be lowered if encryption is being applied to classified information
communicated over the infrastructure (i.e. data in transit encryption). Note this does NOT change the classification of the data itself, only the
physical protection requirements.
8.3.3.R.03.
Rationale
It is important to note that physical controls do not provide any protection against malicious software or other malicious entities that may be
residing on or have access to the system.
8.3.3.R.04.
Rationale
If classified information being communicated over the infrastructure is not encrypted the malicious entry can capture, corrupt or modify the
traffic to assist in furthering any attempts to exploit the network and the information being communicated across it.
8.3.3.C.01.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:1373]
Agencies MUST certify the physical security of facilities containing network infrastructure to the highest classification of information being
communicated over the network infrastructure.