Some RFID systems may cover several organisations, for example in supply chains. In such cases, multiple organisations may require access to
databases that contain tag identifiers and passwords. The security architecture should incorporate strong security controls including the
authentication of external entities, incident management, audit logging and other essential security controls.
11.6.60.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:2962]
Agencies MUST develop a strong security architecture to protect RFID databases and RFID systems.
11.6.60.C.02. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:2963]
Agencies MUST minimise the information stored on RFID tags and in the RFID subsystem.
11.6.60.C.03. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2964]
Agencies SHOULD disable any rewrite functions on RFID devices.
11.6.60.C.04. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2965]
Agencies SHOULD apply the access control requirements of the NZISM C
( hapter 11 - Communications Systems and Devices) to RFID systems.
11.6.61. Policy
11.6.61.R.01. Rationale
An RFID Usage Policy is an essential component of an agency’s privacy policy, addressing topics such as how personal information is stored and
shared. The RFID usage policy should also address privacy issues associated with the tag identifier formats and the potential disclosure of
information based solely on the tag identifier format selected. Agencies MAY be required to ensure that devices that collect and store data
comply with relevant regulation and guidance, such as the Privacy Act and the HIPAA. Refer also to Chapter 20 – Data Management.
11.6.61.R.02. Rationale
Any RFID implementation should also be incorporated into the agency’s security policies. Refer also toChapter 5 – Information Security
Documentation.
11.6.61.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2969]
Agencies SHOULD develop, implement and maintain an RFID Usage Policy.
11.6.61.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2970]
Agencies SHOULD incorporate RFID into the agency’s security policies and information security documentation.
11.6.62. Inspections
11.6.62.R.01. Rationale
Many system component manufacturers use RFID tags to track shipments. RFID tags may be embedded in the packaging, printed on the
reverse of labels, attached to or embedded in the device itself. The ability to identify and track devices may pose a security concern for secure
areas or equipment deployed in high security applications.
11.6.62.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST
[CID:2973]
Agencies MUST conduct visual and technical inspections of packaging and devices to determine if RFID devices have been attached and either
permanently disable or remove such devices.
11.6.62.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2974]
Agencies SHOULD conduct visual inspections of packaging and devices to determine if RFID devices have been attached and if these RFID
devices pose a security concern.
11.6.62.C.03. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2975]
Agencies SHOULD conduct visual inspections of packaging and devices to determine if RFID devices or labelling have been tampered with and
whether this is a security concern.
11.6.63. Shielding
11.6.63.R.01. Rationale
RF shielding is designed to limit the propagation of RF signals outside of the shielded area. Shielding helps to prevent unauthorised reading,
access to or modification of the RFID tag data or interfering with RFID readers. Shielding can be applied to small, individual items, such as
passports and credit cards or to large elements such as shipping containers. The requirement for shielding is determined by the risk
assessment and an engineering assessment.
11.6.63.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2978]
Agencies SHOULD consider undertaking an RF engineering assessment where security concerns exist or where the RFID systems are to be used
in areas with high levels of RF activity.
11.6.63.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2979]
Shielding SHOULD be considered where eavesdropping or RF radiation is a concern, as determined by the risk assessment.
11.6.64. Positioning of Tags and Readers
11.6.64.R.01. Rationale
In order to minimise unnecessary electromagnetic radiation tags and readers should be carefully positioned. Care should be taken in use of
RFID readers in proximity to:
Fuel, ordnance, and other hazardous materials,
Humans and sensitive products (e.g., blood, medicine) that may be harmed by sustained exposure to RF radiation,