13.4.18. Non-volatile flash memory & FPGA media sanitisation
13.4.18.R.01. Rationale
The following guidance applies in cases where media is to be redeployed.
Wear levelling ensures that writes are distributed evenly across each memory block in flash memory. Where possible flash memory SHOULD be
overwritten with a pseudo random pattern twice, rather than once, as this helps to ensure that all memory blocks are overwritten during
sanitisation. Verification is provided by read-back.
13.4.18.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:4215]
Agencies MUST sanitise non-volatile flash memory media by overwriting the media at least twice in its entirety with a pseudo random pattern,
followed by a read back for verification.
13.4.19. Treatment of non-volatile flash memory & FPCA media following sanitisation
13.4.19.R.01. Rationale
The following guidance applies in cases where media is to be redeployed.
Owing to the use of wear levelling in flash memory, it is possible that not all physical memory locations are written to when attempting to
overwrite the media. Classified information can therefore remain on the media. It is for these reasons that TOP SECRET, SECRET and
CONFIDENTIAL flash memory media MUST always remain at their respective classification, even after sanitisation.
13.4.19.R.02. Rationale
Non-volatile flash memory may be redeployed within systems of the same classification only afterall manufacturer's sanitation procedures
have been followed. Destruction and Disposal are covered in sections 13.5 - Media Destruction and 13.6 - Media Disposal respectively.
13.4.19.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:4218]
Following sanitisation, non-volatile flash memory media MUST be treated as indicated in the table below.
Pre-sanitisation classification
Post-sanitisation classification
New Zealand Eyes Only (NZEO) Endorsement
NZEO
TOP SECRET
TOP SECRET
SECRET
SECRET
CONFIDENTIAL
CONFIDENTIAL
RESTRICTED
UNCLASSIFIED
13.4.19.C.02. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:5426]
Where manufacturer sanitation procedures cannot be determined, items MUST be destroyed.
13.4.20. Sanitising solid state drives
13.4.20.R.01. Rationale
Solid state drives operate a Flash Translation Layer (FTL) to interface with the storage devices – usually NAND chips. Current sanitation
techniques address the FTL, rather than destroying the underlying data. It is possible to bypass the FTL, thus accessing the underlying data.
With current technology, there is no effective means of sanitising solid state drives.
13.4.20.R.02. Rationale
Solid state drives also use wear equalisation or levelling techniques which can leave data remnants.
13.4.20.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:4222]
Solid state drives MUST be destroyed before disposal.
13.4.20.C.02. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:4223]
Solid state drives MUST be sanitised using ATA Secure Erase sanitation software before redeployment.
13.4.20.C.03. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST NOT
[CID:4224]
Solid state drives MUST NOT be redeployed in a lower classification environment.
13.4.21. Hybrid Drives
13.4.21.R.01. Rationale
Hybrid drives combine solid state memory devices with magnetic disk technologies. As such they are subject to the same difficulties in effective
sanitisation as solid state devices.
13.4.21.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:4227]
Hybrid drives MUST be treated as solid state drives for sanitisation purposes.
13.4.22. Sanitising media and IT Equipment prior to reuse
13.4.22.R.01. Rationale
Sanitising media and IT Equipment prior to reuse at the same or higher classification assists with enforcing the need-to-know principle within