10.1.49. Audio secure areas
10.1.49.R.01. Rationale
Audio secure areas are designed to prevent audio conversation from being heard outside the walls. Penetrating an audio secure area for cables
in an unapproved manner can degrade this. Consultation with GCSB needs to be undertaken before any modifications are made to audio secure
areas.
10.1.49.C.01. ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:2249]
When penetrating an audio secure area for cables, agencies MUST comply with all directions provided by GCSB.
10.1.50. Wall outlet terminations
10.1.50.R.01. Rationale
Wall outlet boxes are the preferred method of connecting cable infrastructure to workstations and other equipment. They allow the
management of cabling and can utilise a variety of connector types for allocation to different classifications.
10.1.50.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:2253]
Cable groups sharing a wall outlet MUST use different connectors for systems of different classifications.
10.1.50.C.02. ControlSystem Classification(s): Top Secret; Compliance: MUST
[CID:2254]
In areas containing outlets for both TOP SECRET systems and systems of other classifications, agencies MUST ensure that the connectors for
the TOP SECRET systems are different to those of the other systems.
10.1.50.C.03. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST
[CID:2255]
Cable outlets MUST be labelled with the system classification and connector type.
10.1.50.C.04. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2256]
Cable outlets SHOULD be labelled with the system classification and connector type.
10.1.51. Power Filters
10.1.51.R.01. Rationale
Power filters are used to provide a filtered (clean) power supply and reduce opportunity for technical attacks. See also10.1.32.
10.1.51.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:5899]
Power filters SHOULD be used to provide a filtered power supply and reduce opportunity for technical attacks.
10.2. Cable Management for Non-Shared Government Facilities
Objective
10.2.1. Cable management systems in non-shared government facilities are implemented in a secure and easily inspectable and maintainable way.
Context
Scope
10.2.2. This section provides specific requirements for cabling installed in non-shared Government facilities.
A non-shared facility is a facility occupied solely by a single agency.
A shared facility is a facility occupied by more than one agency. A shared facility should have stricter physical and technical security controls
than a non-shared facility.
10.2.3. This section is to be applied in addition to common requirements for cabling as outlined in theSection 10.1 - Cable Management Fundamentals.
Applicability of controls within this section
10.2.4. The controls within this section are only applicable to communications infrastructure located within facilities in New Zealand. For deployable platforms
or facilities outside of New Zealand, Emanation Security Threat Assessments (Section 10.7) of this chapter of this manual will need to be consulted.
References
10.2.5. Further references can be found at:
Reference
NZCSS 400
Title
New Zealand Communications
AS/NZS 3000:2007/Amdt 2:2012
Publisher
GCSB
Source
GCSB
Security Standard No 400
CONFIDENTIAL document available
(Document classified
on application to authorised
CONFIDENTIAL)
personnel
Electrical Installations (Known
as the Australia/New Zealand
Standards NZ
https://www.standards.govt.nz/
Wiring Rules
Rationale & Controls
10.2.6.
Cabling Inspection
10.2.6.R.01.
100
Rationale
Version_3.5__January-2022
Select target paragraph3
Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents