18.6.8. Assurance requirements 18.6.8.R.01. Rationale When accessing multiple systems through a peripheral switch it is important that sufficient assurance is available in the operation of the switch to ensure that information does not accidently pass between the connected systems. 18.6.8.R.02. Rationale It is important to maintain the integrity of Trust Zones and adhere to the principles of separation and segregation in order to avoid inadvertently compromising Trust Zones – even if they are at the same level of classification. 18.6.8.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST [CID:4051] Agencies accessing a classified system and a less classified system via a peripheral switch MUST use an evaluated product with a level of assurance as indicated in the table below. High System Low system / Alternate Trust Domain Required Level of Assurance RESTRICTED UNCLASSIFIED EAL2 or PP CONFIDENTIAL UNCLASSIFIED high assurance RESTRICTED high assurance CONFIDENTIAL high assurance UNCLASSIFIED high assurance RESTRICTED high assurance CONFIDENTIAL high assurance SECRET high assurance UNCLASSIFIED high assurance RESTRICTED high assurance CONFIDENTIAL high assurance SECRET high assurance TOP SECRET high assurance SECRET TOP SECRET 18.6.9. Assurance requirements for NZEO systems 18.6.9.R.01. Rationale NZEO systems are particularly sensitive. Additional security measures need to be put in place when connecting them to other systems. 18.6.9.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST [CID:4058] Agencies accessing a system containing NZEO information and a system of the same classification that is not accredited to process NZEO information, MUST use an evaluated product with an EAL2 (or higher) or a PP level of assurance. 18.6.10. Cross-Connecting Systems with a device other than a KVM 18.6.10.R.01. Rationale Cross-connecting systems with any device other than a KVM approved gateway or an approved cross-domain solution may be high risk, may compromise the integrity of Trust Zones, and may create an electrical hazard. System Classification(s): All Classifications; Compliance: MUST 18.6.10.C.01. Control [CID:4066] Cross-connection of security domains and Trust Zones MUST be enabled through an approved KVM, Gateway or Cross-Domain solution only. High system RESTRICTED Low system/ Alternate Trust Domain Level of assurance UNCLASSIFIED EAL2 or PP UNCLASSIFIED high assurance RESTRICTED high assurance CONFIDENTIAL high assurance UNCLASSIFIED high assurance RESTRICTED high assurance & all lower classifications CONFIDENTIAL SECRET 278 Version_3.5__January-2022

Select target paragraph3

Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents