Guidelines for Physical Security Facilities and systems Physical access to systems The application of the defence-in-depth principle to the protection of systems is enhanced through the use of successive layers of physical security. The first layer of physical security being the use of a security zone for facilities containing systems. Deployable platforms should also meet physical security requirements. Notably, physical security certification authorities dealing with deployable platforms may have specific requirements that supersede the security controls in these guidelines. This may include perimeter controls, building standards and manning levels. As such, an organisation implementing deployable platforms should contact their physical security certification authority to seek additional guidance. Security Control: ISM-0810; Revision: 5; Updated: Dec-21; Applicability: O, P, S, TS; Essential Eight: N/A Systems are secured in facilities that meet the requirements for a security zone suitable for their sensitivity or classification. Physical access to servers, network devices and cryptographic equipment The second layer of physical security is the use of an additional security zone for a server room or communications room. This is then further supplemented by the use of security containers or secure rooms for the protection of servers, network devices and cryptographic equipment. Security Control: ISM-1053; Revision: 3; Updated: Dec-21; Applicability: O, P, S, TS; Essential Eight: N/A Servers, network devices and cryptographic equipment are secured in server rooms or communications rooms that meet the requirements for a security zone suitable for their sensitivity or classification. Security Control: ISM-1530; Revision: 1; Updated: Dec-21; Applicability: O, P, S, TS; Essential Eight: N/A Servers, network devices and cryptographic equipment are secured in security containers or secure rooms suitable for their sensitivity or classification taking into account the combination of security zones they reside in. Security Control: ISM-0813; Revision: 4; Updated: Dec-21; Applicability: All; Essential Eight: N/A Server rooms, communications rooms, security containers and secure rooms are not left in unsecured states. Security Control: ISM-1074; Revision: 3; Updated: Dec-21; Applicability: All; Essential Eight: N/A Keys or equivalent access mechanisms to server rooms, communications rooms, security containers and secure rooms are appropriately controlled. Physical access to network devices in public areas Unprotected network devices in public areas could lead to accidental or deliberate physical damage resulting in an interruption of services. Alternatively, unauthorised access to network devices may allow an adversary to reset them to factory default settings, thereby removing any security controls, or connect directly to them in order to bypass network access controls. Even if access to network devices is not gained by resetting them to factory default settings, it is highly likely that it will cause an interruption of services. Physical access to network devices can be restricted through physical security controls, such as using enclosures that prevent access to their console ports and factory reset buttons, mounting them on ceilings or behind walls, or securing them in security containers. Security Control: ISM-1296; Revision: 3; Updated: Dec-21; Applicability: All; Essential Eight: N/A 25

Select target paragraph3

Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents