10.5.8.R.01. Rationale Labelling cables with the correct socket number, equipment type, source or destination minimises the likelihood of improperly cross connecting equipment and can assist in fault finding and configuration management. 10.5.8.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST [CID:2400] Agencies MUST label cables at each end, with sufficient information to enable the physical identification and inspection of the cable. 10.5.8.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2401] Agencies SHOULD label cables at each end, with sufficient information to enable the physical identification and inspection of the cable. 10.5.9. Cable register 10.5.9.R.01. Rationale Cable registers provide a source of information that assessors can view to verify compliance. 10.5.9.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST [CID:2404] Agencies MUST maintain a register of cables. 10.5.9.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2405] Agencies SHOULD maintain a register of cables. 10.5.10. Cable register contents 10.5.10.R.01. Rationale Cable registers allow installers and assessors to trace cabling for inspection, tampering or accidental damage. It tracks all cable management changes through the life of the system. 10.5.10.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST [CID:2408] The cable register MUST record at least the following information: cable identification number; classification; socket number, equipment type, source or destination site/floor plan diagram; and seal numbers if applicable. 10.5.10.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2409] The cable register SHOULD record at least the following information: cable identification number; classification; socket number, equipment type, source or destination site/floor plan diagram; and seal numbers if applicable. 10.5.11. Cable inspections 10.5.11.R.01. Rationale Regular cable inspections, are a method of checking the cable management system against the cable register as well as detecting tampering, damage, breakages or other anomalies. 10.5.11.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2412] Agencies SHOULD inspect cables for inconsistencies with the cable register in accordance with the frequency defined in the SSP. 10.6. Patch Panels, Patch Cables and Racks Objective 10.6.1. Cable termination, patch panels, patch cables and racks are designed to prevent emanations, cross-connecting or cross-patching systems of differing classifications as well as following good engineering practice. Context Scope 10.6.2. This section covers information relating to the configuration and installation of patch panels, patch cables and fly leads associated with communications systems. 10.6.3. Reference should also be made to: Section 8.5 – Tamper-evident seals; Section 10.1 – Cable management fundamentals; Section 10.7 – Emanation Security Threat Assessments. Applicability of controls within this section 10.6.4. The controls within this section are applicable to all communications infrastructure located within facilities in New Zealand. For deployable platforms or facilities outside New Zealand the Emanation Security Threat Assessments (Section 10.7) of this chapter of this manual MUST be consulted. Exception for patch cable and fly lead connectors 106 Version_3.5__January-2022

Select target paragraph3

Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents