Regular inspections of cable installations are necessary to detect any unauthorised or malicious tampering or cable degradation. 10.2.6.C.01. ControlSystem Classification(s): Top Secret; Compliance: MUST [CID:2270] In TOP SECRET areas or zones, all cabling MUST be inspectable at a minimum of five-metre intervals. 10.2.6.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2271] Cabling SHOULD be inspectable at a minimum of five-metre intervals. 10.2.7. Cables sharing a common reticulation system 10.2.7.R.01. Rationale Laying cabling in a neat and controlled manner, observing separation requirements, allows for inspections and reduces the need for individual cable trays for each classification. 10.2.7.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2274] Approved cable groups may share a common reticulation system but SHOULD have either a dividing partition or a visible gap between the differing cable groups or bundles. 10.2.8. Cabling in walls 10.2.8.R.01. Rationale Cabling run correctly in walls allows for neater installations while maintaining separation and inspectability requirements. 10.2.8.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:2277] Flexible or plastic conduit SHOULD be used in walls to run cabling from cable trays to wall outlets. 10.2.9. Cabinet separation 10.2.9.R.01. Rationale Having a definite gap between cabinets allows for ease of inspections for any unauthorised or malicious cabling or cross patching. 10.2.9.C.01. ControlSystem Classification(s): Top Secret; Compliance: SHOULD [CID:2280] TOP SECRET cabinets SHOULD have a visible inspectable gap between themselves and lower classified cabinets. 10.2.10. Power Filters 10.2.10.R.01. Rationale Power filters are used to provide a filtered (clean) power supply and reduce opportunity for technical attacks. See also10.1.32. 10.2.10.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD [CID:5902] Power filters SHOULD be used to provide a filtered power supply and reduce opportunity for technical attacks. 10.3. Cable Management for Shared Government Facilities Objective 10.3.1. Cable management systems in shared government facilities are implemented in a secure and easily inspectable and maintainable way. Context Scope 10.3.2. This section provides specific requirements for cabling installed in shared Government facilities. A shared facility is a facility occupied by more than one agency. A shared facility should have stricter physical and technical security controls than a non-shared facility. A non-shared facility is a facility occupied solely by a single agency. 10.3.3. This section is to be applied in addition to common requirements for cabling as outlined in theSection 10.1 - Cable Management Fundamentals. Applicability of controls within this section 10.3.4. The controls within this section are applicable only to communications infrastructure located within facilities in New Zealand. For deployable platforms or facilities outside of New Zealand, Emanation Security Threat Assessments (Section 10.7) of this chapter of this manual will need to be consulted. Rationale & Controls 10.3.5. Use of fibre optic cabling 10.3.5.R.01. Rationale Fibre optic cabling does not produce and is not influenced by electromagnetic emanations; as such it offers the highest degree of protection from electromagnetic emanation effects especially in a shared facility where you do not have total control over other areas of the facility. 10.3.5.R.02. Rationale It is more difficult to tap than copper cabling. 10.3.5.R.03. Rationale Many more fibres can be run per cable diameter than wired cables thereby reducing cable infrastructure costs. 10.3.5.R.04. 101 Rationale Version_3.5__January-2022

Select target paragraph3

Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents