8.4.8.
Accounting for IT equipment
8.4.8.R.01.
Rationale
Ensuring that IT equipment containing media is accounted for by using asset registers, equipment registers, operational & configuration records
and regular audits will assist in preventing loss or theft, or in the cases of loss or theft, alerting appropriate authorities to its loss or theft.
8.4.8.R.02.
Rationale
Asset registers may not provide a complete record as financial limits may result in smaller value items not being recorded. In such cases other
registers and operational information can be utilised to assist in building a more complete record.
8.4.8.C.01.
System Classification(s): All Classifications; Compliance: MUST
Control
[CID:1400]
Agencies MUST account for all IT equipment containing media.
8.4.9.
Processing requirements
8.4.9.R.01.
Rationale
As the media within IT equipment takes on the classification of the information it is processing, the area that it is used within needs to be
certified to a level that is appropriate for the classification of that information.
8.4.9.C.01.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:1407]
Agencies MUST certify the physical security of facilities containing IT equipment to the highest classification of information being processed,
stored or communicated by the equipment within the facilities.
8.4.10.
Storage requirements
8.4.10.R.01.
Rationale
The PSR states that either Class C, B or A secure rooms or Class C, B or A security containers or lockable commercial cabinets can be used to
meet physical security requirements for the storage of IT equipment containing media. The class of secure room or security container will
depend on the physical security certification of the surrounding area and the classification of the information.
8.4.10.C.01.
ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:1403]
Agencies MUST ensure that when secure areas are non-operational or when work areas are unoccupied IT equipment with media is secured in
accordance with the minimum physical security requirements for storing classified information as specified in the PSR Management protocol for
physical security – Physical Security of your ICT assets and facilities, with supporting document – Storage requirements for electronic
information in ICT facilities.
8.4.11.
Securing non-volatile media for storage
8.4.11.R.01.
Rationale
The use of techniques to prevent the storage of classified information on non-volatile media and processes to delete temporary data at logoff or
shutdown may sound secure but there is no guarantee that they will always work effectively or will not be bypassed in unexpected
circumstances such as a loss of power. As such, agencies need to consider these risks when implementing such a solution.
8.4.11.C.01.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:1409]
Agencies choosing to prevent the storage of classified information on non-volatile media and enforcing scrubbing of temporary data at logoff or
shutdown SHOULD:
assess the security risks associated with such a decision; and
specify the processes and conditions for their application within the system’s SSP.
8.4.12.
Securing volatile media for storage
8.4.12.R.01.
Rationale
If agencies need to conduct a security risk assessment as part of the procedure for storing IT equipment containing media during non-operation
hours, they should consider security risks such as:
an attacker gaining access to the IT equipment immediately after power is removed and accessing the contents of volatile media to
recover encryption keys or parts thereof. This is sometimes described as a data remanence attack;
extreme environmental conditions causing data to remain in volatile media for extended periods after the removal of power; and
the physical security of the locations in which the IT equipment will reside.
8.4.12.C.01.
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:1412]
Agencies securing volatile media for IT equipment during non-operational hours SHOULD:
disconnect power from the equipment the media resides within;
assess the security risks if not sanitising the media; and
specify any additional processes and controls that will be applied within the system’s SSP.
8.4.13.
Encrypting media within IT equipment
8.4.13.R.01.
Rationale
Current industry good practice is to encrypt all media within IT equipment. Newer operating systems provide this functionality and older
operating systems can be supported with the use of open source or proprietary applications.
8.4.13.C.01.
82
ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:1415]
Version_3.5__January-2022