PSR Mandatory
INFOSEC1, INFOSEC2, INFOSEC3, INFOSEC4,
http://www.protectivesecurity.govt.nz
Requirements
PHYSEC1 and PHYSEC2
https://www.protectivesecurity.govt.nz/information-security/mandatoryrequirements-2/
https://www.protectivesecurity.govt.nz/physical-security/physical-securitymandatory-requirements-2/
PSR content
Management protocol for information
https://www.protectivesecurity.govt.nz/information-security/management-protocol/
protocols
security
Management protocol for physical security
https://www.protectivesecurity.govt.nz/physical-security/management-protocol/
PSR requirements
Security zones
https://www.protectivesecurity.govt.nz/security-zones/
Managing specific
Secure your ICT facilities
https://www.protectivesecurity.govt.nz/physical-security/specific-scenarios/physical-
scenarios
Physical Security for ICT systems
security-for-ict/secure-your-ict-facilities/
https://www.protectivesecurity.govt.nz/physical-security/specific-scenarios/physical-
sections
security-for-ict/
Rationale & Controls
10.1.42. Backbone
10.1.42.R.01. Rationale
The design of a backbone requires consideration of a number of criteria including the capacity of the cable to carry the predicted volume of
data at acceptable speeds. An element of “future proofing” is also required as re-cabling to manage capacity issues can be costly. Fibre optic
cable provides a convenient means of securing and “future proofing” backbones.
10.1.42.C.01. ControlSystem Classification(s): Confidential, Secret, Top Secret; Compliance: MUST
[CID:2216]
Agencies MUST use fibre optic cable for backbone infrastructures and installations.
10.1.42.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2217]
Agencies SHOULD use fibre optic cable for backbone infrastructures and installations.
10.1.43. Use of Fibre Optic Cable
10.1.43.R.01. Rationale
Fibre optic cable is considered more secure than copper cables and provides electrical isolation of signals. Fibre will also provide higher
bandwidth and speed to allow a degree of future-proofing in network design.
10.1.43.C.01. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2220]
Agencies SHOULD use fibre optic cabling.
10.1.43.C.02. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2221]
Agencies SHOULD consult with the GCSB where fibre optic cable incorporating conductive metal strengtheners or sheaths is specified.
10.1.43.C.03. ControlSystem Classification(s): All Classifications; Compliance: SHOULD
[CID:2222]
Agencies SHOULD consult with the GCSB where copper cables are specified.
10.1.43.C.04. ControlSystem Classification(s): All Classifications; Compliance: SHOULD NOT
[CID:2223]
Agencies SHOULD NOT use fibre optic cable incorporating conductive metal strengtheners or sheaths except where essential for cable integrity.
10.1.44. Cabling Standards
10.1.44.R.01. Rationale
Unauthorised personnel could inadvertently or deliberately access system cabling. This could result in loss or compromise of classified
information. Non-detection of covert tampering or access to system cabling may result in long term unauthorised access to classified
information by a hostile entity.
10.1.44.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:2226]
Agencies MUST install all cabling in accordance with the relevant New Zealand standards as directed by AS/NZS 3000:2007 and NZCSS400.
10.1.45. Cable colours
10.1.45.R.01. Rationale
To facilitate cable management, maintenance and security cables and conduit should be colour-coded to indicate the classification of the data
carried and/or classification of the compartmented data.
10.1.45.R.02. Rationale
Cables and conduit may be the distinguishing colour for their entire length or display a distinguishing label marking and colour at each end and
at a maximum of two metre intervals along the cable.
10.1.45.C.01. ControlSystem Classification(s): All Classifications; Compliance: MUST
[CID:2230]
Agencies MUST comply with the cable and conduit colours specified in the following table.
Classification
97
Cable colour
Version_3.5__January-2022
Select target paragraph3
Connect to a paragraph
Connect to an entity
Disable highlights