Figure 11: Separation of RED/BLACK Separation of Cable Runs 10.6.19. In order to maintain the integrity of RED/BLACK separation, cables for power and data should be separately bundled as powerRED or BLACK and data RED or BLACK. Cables should be run with as much distance between the bundles as can be practically managed, within the constraints of cable feeds and rack configuration. Ideally RED and BLACK should be on opposite sides of the rack. Cables should be no longer than required to avoid overlength cables compromising separation. Access to BLACK equipment and components by uncleared staff and contractors 10.6.20. In some instances there may be a requirement for external technical or other uncleared personnel to accessBLACK equipment and components for servicing, repair or replacement. Care must be taken to maintain the integrity of RED equipment and components. This can be especially problematic in shared rack configurations as described above. This requirement should be identified before installation takes place and segregation measures implemented. Ideally physical separation ofBLACK from RED is the best solution, recognising however, this may not always be possible or practical. Other solutions may include, for example, a shared rack that has two doors with the RED door locked and alarmed so that BLACK equipment can be accessed without compromising the security ofRED equipment. Discussion with the GCSB may identify other practical solutions. References 10.6.21. Further References avaliable below: Reference ISO/IEC 11801-5:2017 Title Data centres Publisher ISO Source https://www.iso.org/standard/62247. html ISO/IEC TR 14763-2-1:2011 Information technology -- ISO Implementation and operation of customer premises cabling -- https://www.iso.org/standard/55236. html Part 2-1: Planning and installation - Identifiers within administration systems ANSI/TIA-606-B Administration Standard for the ANSI https://www.ansi.org ANSI https://www.ansi.org Telecommunications Infrastructure of Commercial Buildings ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers PD IEC/TR 62691:2016 Optical fibre cables. Guidelines to the installation of optical fibre cables PD IEC/TR 62362:2010 Selection of optical fibre cable specifications relative to mechanical, ingress, climatic or International Electrotechnical https://www.standards.govt.nz Commission (IEC) Available through Standards New Zealand International Electrotechnical https://www.standards.govt.nz Commission (IEC) Available through Standards New Zealand electromagnetic characteristics. Guidance 108 Version_3.5__January-2022

Select target paragraph3

Connect to a paragraph
Connect to an entity
Disable highlights
Add to table of contents